- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
KSh92,000.00 Excl. VAT
Ctec 1 Loop Addressable Fire Panel
SKU: N/ACtec 1 Loop Addressable Fire Panel
KSh87,000.00 Excl. VAT
Ctec EP203 Automatic Extinguisher Panel
SKU: N/ACtec EP203 Automatic Extinguisher Panel
KSh240,000.00 Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
SKU: N/AMorley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
KSh290,000.00 Excl. VAT
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
SKU: 20A12DDS10D0031 084PCTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh6,200.00 C-TEC CA470 Cast Addressable Manual Call Point
SKU: N/AC-Tec CA470 CAST Addressable Manual Call Point Features
KSh15,000.00 Excl. VAT
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
SKU: N/AC-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh6,500.00 Excl. VAT
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
SKU: N/AMI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel
KSh92,000.00 Excl. VAT
Buy Now

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh290,000.00 Excl. VAT
Buy Now

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features
KSh6,200.00 KSh7,500.00 Excl. VAT
Buy Now

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh15,000.00 Excl. VAT
Buy Now

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh6,500.00 Excl. VAT
Buy Now
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel
KSh92,000.00 Excl. VAT
Buy Now

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh290,000.00 Excl. VAT
Buy Now

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features
KSh6,200.00 KSh7,500.00 Excl. VAT
Buy Now

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh15,000.00 Excl. VAT
Buy Now

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh6,500.00 Excl. VAT
Buy Now
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel
KSh92,000.00 Excl. VAT
Buy Now

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel
KSh87,000.00 Excl. VAT
Read more

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
KSh240,000.00 KSh290,000.00 Excl. VAT
Read more

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh290,000.00 Excl. VAT
Buy Now

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features
KSh6,200.00 KSh7,500.00 Excl. VAT
Buy Now

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh15,000.00 Excl. VAT
Buy Now

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh6,500.00 Excl. VAT
Buy Now
