- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- Quick and Easy Installation
- Vibrating Type
- High Sound Level & Reliability
- Low Power Consumption
- Available in 6”, 8” and 10” Housing
- Mounts to Standard 4” Square Electrical Box
- Cast Alloy Housing
- Indoor or Outdoor* Use
- Electronic linear heat detection
- Remote Indicator output
- Wide voltage range (9.5 ~ 30 V dc)
- Twin fire LEDs allow 360 degree viewing
- Fixed Temperature Detector
- Full range of mounting bases
- Approved by LPCB & VdS
- Also available in white
- A high-quality ionisation smoke detector.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber.
- Certified to EN54-7 by the LPCB.
- Wide 9-33V DC operating voltage.
- Red LED illuminates when the detector is in alarm.
- Requires a 45681-201APO diode base, 45681-200APO non-diode base or 45681-245APO relay base.
- Working Voltage: 9-28VDC
- Dimensions: 140x105x45mm
- Resetable with key HP-CMC2166-6
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
KSh15,000.00 Excl. VAT
ASENWATRE 2 Zone Conventional Fire Panel
SKU: 821ASENWATRE 2 Zone Conventional Fire Panel
KSh3,200.00 Excl. VAT
CTEC Conventional Photoelectric Smoke Detector
SKU: 939CTEC Conventional Photoelectric Smoke Detector
KSh3,200.00 Excl. VAT
CTEC Conventional Heat Detector
SKU: 938CTEC Conventional Heat Detector
KSh25,000.00 Excl. VAT
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
SKU: 937CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.
KSh3,500.00 Excl. VAT
Rectangular Sensored Keyguard
SKU: 935Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111
KSh2,500.00 Excl. VAT
Conventional Electric Fire Bell
SKU: 72Conventional Electric Fire Bell 24 DC
Hochiki conventional sounder/beacon
SKU: 68Hochiki conventional sounder/beacon
Conventional wall sounder beacon with improved electronic design wich enables very low current consumption whilst providing a range of tones and volumens – selectable from the DIL switches on each unit. The unitis supplied with its own base, a shallow base (IP43) or a deep base (IP65).
KSh2,500.00 Excl. VAT
Hochiki Conventional heat detector
SKU: 67Hochiki Conventional heat detector
KSh5,800.00 Excl. VAT
Apollo Series 65 ionisation smoke detector(Conventional)
SKU: 391Apollo Series 65 ionisation smoke detector (Conventional)
KSh4,500.00 Excl. VAT
ASENWARE Conventional Manual Call Point Push Station
SKU: 555ASENWARE Conventional Manual Call Point Push Station
KSh1,200.00 Asenware Convectional heat detector AW-CTD382
SKU: N/A
KSh22,000.00 INIM Conventional control panel with 4 zones expandable to 20
SKU: N/AINIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).
KSh18,000.00 Non-expandable 2 zone conventional control panel – SmartLine020-2
SKU: N/ASmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).
KSh45,000.00 Excl. VAT
C-TEC Standard 8 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 8 Zone Conventional Fire Alarm Panel
KSh35,000.00 Excl. VAT
C-TEC Standard 4 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 4 Zone Conventional Fire Alarm Panel
KSh25,000.00 Excl. VAT
Asenware 8 Zone Fire alarm control Panel
SKU: N/AAsenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
KSh18,000.00 Excl. VAT
Asenware 4 Zone Fire Alarm Control Panel
SKU: N/AAsenware 4 Zone Fire Alarm Control Panel
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- Quick and Easy Installation
- Vibrating Type
- High Sound Level & Reliability
- Low Power Consumption
- Available in 6”, 8” and 10” Housing
- Mounts to Standard 4” Square Electrical Box
- Cast Alloy Housing
- Indoor or Outdoor* Use
- Electronic linear heat detection
- Remote Indicator output
- Wide voltage range (9.5 ~ 30 V dc)
- Twin fire LEDs allow 360 degree viewing
- Fixed Temperature Detector
- Full range of mounting bases
- Approved by LPCB & VdS
- Also available in white
- A high-quality ionisation smoke detector.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber.
- Certified to EN54-7 by the LPCB.
- Wide 9-33V DC operating voltage.
- Red LED illuminates when the detector is in alarm.
- Requires a 45681-201APO diode base, 45681-200APO non-diode base or 45681-245APO relay base.
- Working Voltage: 9-28VDC
- Dimensions: 140x105x45mm
- Resetable with key HP-CMC2166-6
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

Conventional Electric Fire Bell
Conventional Electric Fire Bell 24 DC
Hochiki conventional sounder/beacon
Hochiki conventional sounder/beacon
Conventional wall sounder beacon with improved electronic design wich enables very low current consumption whilst providing a range of tones and volumens – selectable from the DIL switches on each unit. The unitis supplied with its own base, a shallow base (IP43) or a deep base (IP65).

Hochiki Conventional heat detector
Hochiki Conventional heat detector

Apollo Series 65 ionisation smoke detector(Conventional)
Apollo Series 65 ionisation smoke detector (Conventional)

ASENWARE Conventional Manual Call Point Push Station
ASENWARE Conventional Manual Call Point Push Station

Asenware Convectional heat detector AW-CTD382

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- Quick and Easy Installation
- Vibrating Type
- High Sound Level & Reliability
- Low Power Consumption
- Available in 6”, 8” and 10” Housing
- Mounts to Standard 4” Square Electrical Box
- Cast Alloy Housing
- Indoor or Outdoor* Use
- Electronic linear heat detection
- Remote Indicator output
- Wide voltage range (9.5 ~ 30 V dc)
- Twin fire LEDs allow 360 degree viewing
- Fixed Temperature Detector
- Full range of mounting bases
- Approved by LPCB & VdS
- Also available in white
- A high-quality ionisation smoke detector.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber.
- Certified to EN54-7 by the LPCB.
- Wide 9-33V DC operating voltage.
- Red LED illuminates when the detector is in alarm.
- Requires a 45681-201APO diode base, 45681-200APO non-diode base or 45681-245APO relay base.
- Working Voltage: 9-28VDC
- Dimensions: 140x105x45mm
- Resetable with key HP-CMC2166-6
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

Conventional Electric Fire Bell
Conventional Electric Fire Bell 24 DC
Hochiki conventional sounder/beacon
Hochiki conventional sounder/beacon
Conventional wall sounder beacon with improved electronic design wich enables very low current consumption whilst providing a range of tones and volumens – selectable from the DIL switches on each unit. The unitis supplied with its own base, a shallow base (IP43) or a deep base (IP65).

Hochiki Conventional heat detector
Hochiki Conventional heat detector

Apollo Series 65 ionisation smoke detector(Conventional)
Apollo Series 65 ionisation smoke detector (Conventional)

ASENWARE Conventional Manual Call Point Push Station
ASENWARE Conventional Manual Call Point Push Station

Asenware Convectional heat detector AW-CTD382

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- Quick and Easy Installation
- Vibrating Type
- High Sound Level & Reliability
- Low Power Consumption
- Available in 6”, 8” and 10” Housing
- Mounts to Standard 4” Square Electrical Box
- Cast Alloy Housing
- Indoor or Outdoor* Use
- Electronic linear heat detection
- Remote Indicator output
- Wide voltage range (9.5 ~ 30 V dc)
- Twin fire LEDs allow 360 degree viewing
- Fixed Temperature Detector
- Full range of mounting bases
- Approved by LPCB & VdS
- Also available in white
- A high-quality ionisation smoke detector.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber.
- Certified to EN54-7 by the LPCB.
- Wide 9-33V DC operating voltage.
- Red LED illuminates when the detector is in alarm.
- Requires a 45681-201APO diode base, 45681-200APO non-diode base or 45681-245APO relay base.
- Working Voltage: 9-28VDC
- Dimensions: 140x105x45mm
- Resetable with key HP-CMC2166-6
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

Conventional Electric Fire Bell
Conventional Electric Fire Bell 24 DC
Hochiki conventional sounder/beacon
Hochiki conventional sounder/beacon
Conventional wall sounder beacon with improved electronic design wich enables very low current consumption whilst providing a range of tones and volumens – selectable from the DIL switches on each unit. The unitis supplied with its own base, a shallow base (IP43) or a deep base (IP65).

Hochiki Conventional heat detector
Hochiki Conventional heat detector

Apollo Series 65 ionisation smoke detector(Conventional)
Apollo Series 65 ionisation smoke detector (Conventional)

ASENWARE Conventional Manual Call Point Push Station
ASENWARE Conventional Manual Call Point Push Station

Asenware Convectional heat detector AW-CTD382

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.