- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
KSh35,000.00 Excl. VAT
C-TEC Standard 4 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 4 Zone Conventional Fire Alarm Panel
KSh25,000.00 Excl. VAT
Asenware 8 Zone Fire alarm control Panel
SKU: N/AAsenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
KSh18,000.00 Excl. VAT
Asenware 4 Zone Fire Alarm Control Panel
SKU: N/AAsenware 4 Zone Fire Alarm Control Panel
KSh1,500.00 Excl. VAT
Break Glass Fire Emergency Door Release Red (CA-A001A)
SKU: N/ABreak Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places
KSh3,500.00 Excl. VAT
Inim conventional Manual Call Point
SKU: N/AInim conventional Manual Call Point
KSh6,500.00 Excl. VAT
Conventional Sounder with Flasher
SKU: N/AConventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level
KSh1,900.00 AW-CTD321 Conventional Fix Temperature Heat Detector
SKU: N/AConventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
KSh1,200.00 Excl. VAT
Asenware Smoke Detector AW-CSD311
SKU: N/AAsenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
KSh1,900.00 Inim Conventional Heat Detector ID200
SKU: N/AInim Conventional Heat Detector ID200
KSh1,500.00 Conventional Optical smoke detector
SKU: N/AConventional Optical smoke detector
KSh240,000.00 Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
SKU: N/AMorley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
KSh290,000.00 Excl. VAT
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
SKU: 20A12DDS10D0031 084PCTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh6,200.00 C-TEC CA470 Cast Addressable Manual Call Point
SKU: N/AC-Tec CA470 CAST Addressable Manual Call Point Features
KSh4,800.00 EC0011E Manual callpoint (IP67)
SKU: N/AEC0011E Manual callpoint for outdoor installation (IP67)
KSh15,000.00 Excl. VAT
Morley Honeywell Addressable Sounder with Flasher
SKU: N/AMorley Honeywell Addressable Sounder with Flasher
KSh8,400.00 ES2000 Addressable wall mount audible/visual-audible alarm indicator
SKU: N/AES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.
KSh15,000.00 Excl. VAT
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
SKU: N/AC-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh6,500.00 Excl. VAT
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
SKU: N/AMI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh4,500.00 Inim ED200 Optical Heat detector
SKU: N/AThe ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.
KSh6,500.00 Excl. VAT
Apollo XP95 Ionisation Smoke Detector
SKU: N/AApollo XP95 Ionisation Smoke Detector
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)

Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector
