- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Medium Red First Aid Kit covering up to 30 people.
- Ideal for Family,
- Construction Site Kit,
- Small office, Recreation
- Sports activities.
- Dimensions: 27cm by 18cm by 12cm
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc
- Bright red for easy identification
- Comes with a hammer, chain, and two keys
- Durable steel box for long-term use
- EXTRA LOUD – 30W, 120dB, Will wake up the dead!
- PREMIUM QUALITY – Premium Quality Siren without the Premium Price
- EASY TO INSTALL – Compact Design. Bracket pivots to 90 degrees.
- DURABLE DESIGN – Weatherproof ABS plastic will last you for years and years.
KSh1,200.00 Excl. VAT
Asenware Smoke Detector AW-CSD311
SKU: N/AAsenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
KSh1,900.00 Inim Conventional Heat Detector ID200
SKU: N/AInim Conventional Heat Detector ID200
KSh1,500.00 Conventional Optical smoke detector
SKU: N/AConventional Optical smoke detector
KSh240,000.00 Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
SKU: N/AMorley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
KSh290,000.00 Excl. VAT
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
SKU: 20A12DDS10D0031 084PCTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh6,200.00 C-TEC CA470 Cast Addressable Manual Call Point
SKU: N/AC-Tec CA470 CAST Addressable Manual Call Point Features
KSh4,800.00 EC0011E Manual callpoint (IP67)
SKU: N/AEC0011E Manual callpoint for outdoor installation (IP67)
KSh15,000.00 Excl. VAT
Morley Honeywell Addressable Sounder with Flasher
SKU: N/AMorley Honeywell Addressable Sounder with Flasher
KSh8,400.00 ES2000 Addressable wall mount audible/visual-audible alarm indicator
SKU: N/AES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.
KSh15,000.00 Excl. VAT
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
SKU: N/AC-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh6,500.00 Excl. VAT
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
SKU: N/AMI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh4,500.00 Inim ED200 Optical Heat detector
SKU: N/AThe ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.
KSh6,500.00 Excl. VAT
Apollo XP95 Ionisation Smoke Detector
SKU: N/AApollo XP95 Ionisation Smoke Detector
KSh150,000.00 Excl. VAT
Carbon dioxide/CO₂ Flooding Fire Suppression System 40L
SKU: N/Acarbon dioxide/CO₂ Flooding Fire Suppression System 40l
IFS’s CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B, and C hazards.
KSh15,000.00 Excl. VAT
2 Zone Fire Alarm Panel AW-CFP2166-2
SKU: N/A2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.
KSh4,500.00 Medium Red/White First Aid Kit
SKU: N/AVisit our shop today (Informed Systems Limited, Uniview Distributors)at Kamae road, off Luthuli Ave, or contact @0745765503.
KSh2,750.00 Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
SKU: N/AHoneywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
KSh2,500.00 Quick Access Break Glass Emergency Key Box with hammer and chain
SKU: N/AQuick Access Break Glass Emergency Key Box with hammer and chain
KSh2,200.00 30 Watt Security Siren Horn Alarm – White
SKU: N/A30 Watt Security Siren features
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Medium Red First Aid Kit covering up to 30 people.
- Ideal for Family,
- Construction Site Kit,
- Small office, Recreation
- Sports activities.
- Dimensions: 27cm by 18cm by 12cm
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc
- Bright red for easy identification
- Comes with a hammer, chain, and two keys
- Durable steel box for long-term use
- EXTRA LOUD – 30W, 120dB, Will wake up the dead!
- PREMIUM QUALITY – Premium Quality Siren without the Premium Price
- EASY TO INSTALL – Compact Design. Bracket pivots to 90 degrees.
- DURABLE DESIGN – Weatherproof ABS plastic will last you for years and years.

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

Carbon dioxide/CO₂ Flooding Fire Suppression System 40L
carbon dioxide/CO₂ Flooding Fire Suppression System 40l
IFS’s CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B, and C hazards.

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Medium Red/White First Aid Kit
Visit our shop today (Informed Systems Limited, Uniview Distributors)at Kamae road, off Luthuli Ave, or contact @0745765503.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,750.00
Quick Access Break Glass Emergency Key Box with hammer and chain
Quick Access Break Glass Emergency Key Box with hammer and chain
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,500.00
30 Watt Security Siren Horn Alarm – White
30 Watt Security Siren features
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Medium Red First Aid Kit covering up to 30 people.
- Ideal for Family,
- Construction Site Kit,
- Small office, Recreation
- Sports activities.
- Dimensions: 27cm by 18cm by 12cm
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc
- Bright red for easy identification
- Comes with a hammer, chain, and two keys
- Durable steel box for long-term use
- EXTRA LOUD – 30W, 120dB, Will wake up the dead!
- PREMIUM QUALITY – Premium Quality Siren without the Premium Price
- EASY TO INSTALL – Compact Design. Bracket pivots to 90 degrees.
- DURABLE DESIGN – Weatherproof ABS plastic will last you for years and years.

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

Carbon dioxide/CO₂ Flooding Fire Suppression System 40L
carbon dioxide/CO₂ Flooding Fire Suppression System 40l
IFS’s CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B, and C hazards.

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Medium Red/White First Aid Kit
Visit our shop today (Informed Systems Limited, Uniview Distributors)at Kamae road, off Luthuli Ave, or contact @0745765503.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,750.00
Quick Access Break Glass Emergency Key Box with hammer and chain
Quick Access Break Glass Emergency Key Box with hammer and chain
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,500.00
30 Watt Security Siren Horn Alarm – White
30 Watt Security Siren features
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Medium Red First Aid Kit covering up to 30 people.
- Ideal for Family,
- Construction Site Kit,
- Small office, Recreation
- Sports activities.
- Dimensions: 27cm by 18cm by 12cm
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc
- Bright red for easy identification
- Comes with a hammer, chain, and two keys
- Durable steel box for long-term use
- EXTRA LOUD – 30W, 120dB, Will wake up the dead!
- PREMIUM QUALITY – Premium Quality Siren without the Premium Price
- EASY TO INSTALL – Compact Design. Bracket pivots to 90 degrees.
- DURABLE DESIGN – Weatherproof ABS plastic will last you for years and years.

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)

Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Inim ED200 Optical Heat detector
The ED200 heat detector can be configured in the following modes: A1R mode (fixed threshold at 58°C with thermovelocimetric detection); B mode (fixed threshold at 72°C); A2S mode (fixed threshold at 58°C); BR mode (fixed threshold at 72°C with thermovelocimetric detection).
As a result of high flexibility, this detector is useful in places where the environment is dusty or smoky and the risk of false alarms is high.

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

Carbon dioxide/CO₂ Flooding Fire Suppression System 40L
carbon dioxide/CO₂ Flooding Fire Suppression System 40l
IFS’s CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B, and C hazards.

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Medium Red/White First Aid Kit
Visit our shop today (Informed Systems Limited, Uniview Distributors)at Kamae road, off Luthuli Ave, or contact @0745765503.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector

Quick Access Break Glass Emergency Key Box with hammer and chain
Quick Access Break Glass Emergency Key Box with hammer and chain

30 Watt Security Siren Horn Alarm – White
30 Watt Security Siren features
