- Meet both EN54-3 and EN54-23.
- Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
- Suitable for wall and ceiling mount applications.
- Providing 16 tones.
- Highly efficient LED technology
-
High-visibility 50 mm FR reflective tape
-
Triple trim design for enhanced visibility in low light
- Size: 75 x100mm / (Max.D*H)
- Weight: 400g
- Buzzer type: Continuous Sound 110dB
- Material: steel material and ABS
- resin Insulation resistance: 100MQ (at500VDC)
- voltage: 500VA0, 50 / 60Hz 1 minute
- Power reaches: 40W
- Protection level: IP44
- Cable Type: Fire Cable
- Wire Gauge: 1.5mm
- Core Configuration: 2 cores
- Length: 100 meters
- Purpose: Specifically designed for fire alarm and detection systems, emergency lighting, and other fire safety applications.
- Fire Resistance: Constructed with materials that provide high fire resistance, ensuring reliable performance and maintaining the integrity of the cable during fire incidents.
- Product: 4 wire LPG gas detector
- Brand: Asenware
- Model Number: AW-D132C-4W
- Power Consumption: ≤2W @Alarm
- Alarm Horn: ≥ 85dB @3m
- Main Voltage: 24V DC
- Alarm Outputs: DC12V pulse voltage and Relay( COM ,NO )
- Warm Up Time: Approximately 90 Seconds
- Size: 104.5mm* 58mm* 29.1mm
- Weight: About 62g
- Conventional Manual Call Point Appearance
- LED Indicator
- Conventional Manual Call Point Working Environment
- This conventional manual call point is suitable for indoor use, in order to better achieve product performance.
- This conventional manual call point complies with the EN54-11 standard
- Soft addressed
- Integral short circuit isolator
- Single address
- Fast fit clip on front cover
- High visibility status LED
- Wide range of accessories
- Heavy duty terminals
- 8 Flow
- DC8 Cylinder + Valve + Activation Mechanism (1 Piece )
- DC8 Wall Mount Bracket (1 Piece )
- Remote Pull Station (1 Piece )
- A Nozzle (6 Piece)
- F Nozzle (1 Piece)
- 182°C ThermoBulb Detector Set (1 Piece )
- Corner Pulley (3 Piece )
- Cylinder + Wet Chemical (1 Piece )
- Wall Mount Bracket (1 Piece)
- Pneumatic Valve (1 Piece )
- Pneumatic Manuel Activation Button (1 Piece)
- Discharge Hose (1 Piece)
- A Nozzle (1 Piece)
- F Nozzle (1 Piece)
- R Nozzle (1 Piece)
- Detection Tube (6×1 mm) (10 meters)
- Robust design
- Low current consumption
- Easy to install
- Maximum 110dB(A) at 1 metre (dependant on tone selected)
- 32 user-selectable tones
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc = 3.8mA.
- IP33C rated.
- Certified to EN54 Parts 11 (LPCB) and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
- A high-quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
- Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. The default setting is A2.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- A high-quality smoke detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
- Smart algorithms help reduce false alarms.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Drift compensation functionality.
- 0.16dB/m sensitivity/obscuration level.
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- 8 zones panels
- Flexible, high specification system
- Surface or semi-flush mounting
- Simple “one-shot” auto-reset user test facility
- Maintenance free poly switch circuit protection, with auto reset
- Class change and programmable fire/fault relay as standard
KSh4,000.00 Excl. VAT
Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)
SKU: N/AAsenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)
KSh9,500.00 Excl. VAT
Fire Beaters
SKU: N/AFire Beaters
A fire beater is a simple firefighting tool designed to suppress small fires by smothering flames and cutting off the oxygen supply. It is commonly used for controlling grass fires, bush fires, and small outdoor fires in farms, forests, and open areas
KSh35,000.00 Excl. VAT
Firefighter Protective Suit (Fireman Suit)
SKU: N/AFirefighter Protective Suit (Fireman Suit)
The firefighter suit is designed to provide maximum protection for professionals during firefighting operations. Designed to withstand extreme conditions, this suit delivers outstanding performance and comfort while combining style and durability.
Visibility & Safety
KSh8,000.00 Excl. VAT
Fireman Gloves
SKU: N/AFireman Gloves
Fireman gloves are specially designed to protect firefighters and emergency responders from extreme heat, flames, sharp objects, and hazardous environments.
KSh1,200.00 Excl. VAT
CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
SKU: N/ACA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/1NC/1COM offers a crucial interface for residents to alert others in case of a fire or emergency to initiate the evacuation of a building, discharge gas, or open a controlled door.
KSh2,500.00 SNG190 Siren
SKU: N/ASNG190 Siren
KSh13,000.00 Excl. VAT
IFS 1.5mm 2 core Fire Cable 100m full copper
SKU: N/AIFS 1.5mm 2 core Fire Cable 100m full copper
KSh12,000.00 Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
SKU: N/AAsenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
KSh1,500.00 Excl. VAT
Asenware Conventional Manual Call Point AW-D135C
SKU: N/AAsenware Conventional Manual Call Point AW-D135C
KSh1,200.00 Excl. VAT
Asenware Conventional Smoke Detector AW-CSD381
SKU: N/AAsenware Conventional Smoke Detector AW-CSD381
Model No. : AW-CSD381
Photo-Electric type spot detector
Built in dual LEDs
Visible from all around 360°
Remote indicator output
Compatible with most brands fire alarm panels.
LPCB approved.
KSh5,500.00 Excl. VAT
Menvier Call Point addressable CBG 370S
SKU: N/AMenvier Call Point addressable CBG 370S
KSh170,000.00 Excl. VAT
Defender DC8S Mechanical Kitchen Suppression System
SKU: N/ADefender DC8S Mechanical Kitchen Suppression System
KSh95,000.00 Excl. VAT
Defender DPSS Pneumatic Kitchen Suppression System
SKU: N/ADefender DPSS Pneumatic Kitchen Suppression System
4 Flows
KSh6,000.00 Excl. VAT
Hochiki Conventional Wall Sounder
SKU: N/AHochiki Conventional Wall Sounder
KSh4,500.00 Excl. VAT
CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)
SKU: N/ACTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)
KSh2,500.00 Excl. VAT
C-Tec Conventional Manual Call Point
SKU: N/AC-Tec Conventional Manual Call Point
KSh5,600.00 C-Tec Addressable Heat Detector
SKU: N/AC-Tec Addressable Heat Detector
KSh5,800.00 C-Tec Addressable Smoke Detector
SKU: N/AC-Tec Addressable Smoke Detector
KSh50,000.00 Excl. VAT
Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
SKU: N/ACooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
- Meet both EN54-3 and EN54-23.
- Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
- Suitable for wall and ceiling mount applications.
- Providing 16 tones.
- Highly efficient LED technology
-
High-visibility 50 mm FR reflective tape
-
Triple trim design for enhanced visibility in low light
- Size: 75 x100mm / (Max.D*H)
- Weight: 400g
- Buzzer type: Continuous Sound 110dB
- Material: steel material and ABS
- resin Insulation resistance: 100MQ (at500VDC)
- voltage: 500VA0, 50 / 60Hz 1 minute
- Power reaches: 40W
- Protection level: IP44
- Cable Type: Fire Cable
- Wire Gauge: 1.5mm
- Core Configuration: 2 cores
- Length: 100 meters
- Purpose: Specifically designed for fire alarm and detection systems, emergency lighting, and other fire safety applications.
- Fire Resistance: Constructed with materials that provide high fire resistance, ensuring reliable performance and maintaining the integrity of the cable during fire incidents.
- Product: 4 wire LPG gas detector
- Brand: Asenware
- Model Number: AW-D132C-4W
- Power Consumption: ≤2W @Alarm
- Alarm Horn: ≥ 85dB @3m
- Main Voltage: 24V DC
- Alarm Outputs: DC12V pulse voltage and Relay( COM ,NO )
- Warm Up Time: Approximately 90 Seconds
- Size: 104.5mm* 58mm* 29.1mm
- Weight: About 62g
- Conventional Manual Call Point Appearance
- LED Indicator
- Conventional Manual Call Point Working Environment
- This conventional manual call point is suitable for indoor use, in order to better achieve product performance.
- This conventional manual call point complies with the EN54-11 standard
- Soft addressed
- Integral short circuit isolator
- Single address
- Fast fit clip on front cover
- High visibility status LED
- Wide range of accessories
- Heavy duty terminals
- 8 Flow
- DC8 Cylinder + Valve + Activation Mechanism (1 Piece )
- DC8 Wall Mount Bracket (1 Piece )
- Remote Pull Station (1 Piece )
- A Nozzle (6 Piece)
- F Nozzle (1 Piece)
- 182°C ThermoBulb Detector Set (1 Piece )
- Corner Pulley (3 Piece )
- Cylinder + Wet Chemical (1 Piece )
- Wall Mount Bracket (1 Piece)
- Pneumatic Valve (1 Piece )
- Pneumatic Manuel Activation Button (1 Piece)
- Discharge Hose (1 Piece)
- A Nozzle (1 Piece)
- F Nozzle (1 Piece)
- R Nozzle (1 Piece)
- Detection Tube (6×1 mm) (10 meters)
- Robust design
- Low current consumption
- Easy to install
- Maximum 110dB(A) at 1 metre (dependant on tone selected)
- 32 user-selectable tones
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc = 3.8mA.
- IP33C rated.
- Certified to EN54 Parts 11 (LPCB) and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
- A high-quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
- Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. The default setting is A2.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- A high-quality smoke detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
- Smart algorithms help reduce false alarms.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Drift compensation functionality.
- 0.16dB/m sensitivity/obscuration level.
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- 8 zones panels
- Flexible, high specification system
- Surface or semi-flush mounting
- Simple “one-shot” auto-reset user test facility
- Maintenance free poly switch circuit protection, with auto reset
- Class change and programmable fire/fault relay as standard

Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)
Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)

Fire Beaters
Fire Beaters
A fire beater is a simple firefighting tool designed to suppress small fires by smothering flames and cutting off the oxygen supply. It is commonly used for controlling grass fires, bush fires, and small outdoor fires in farms, forests, and open areas

Firefighter Protective Suit (Fireman Suit)
Firefighter Protective Suit (Fireman Suit)
The firefighter suit is designed to provide maximum protection for professionals during firefighting operations. Designed to withstand extreme conditions, this suit delivers outstanding performance and comfort while combining style and durability.
Visibility & Safety

Fireman Gloves
Fireman Gloves
Fireman gloves are specially designed to protect firefighters and emergency responders from extreme heat, flames, sharp objects, and hazardous environments.


CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/1NC/1COM offers a crucial interface for residents to alert others in case of a fire or emergency to initiate the evacuation of a building, discharge gas, or open a controlled door.

SNG190 Siren
SNG190 Siren

IFS 1.5mm 2 core Fire Cable 100m full copper
IFS 1.5mm 2 core Fire Cable 100m full copper

Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh12,000.00
Asenware Conventional Manual Call Point AW-D135C
Asenware Conventional Manual Call Point AW-D135C

Asenware Conventional Smoke Detector AW-CSD381
Asenware Conventional Smoke Detector AW-CSD381
Model No. : AW-CSD381
Photo-Electric type spot detector
Built in dual LEDs
Visible from all around 360°
Remote indicator output
Compatible with most brands fire alarm panels.
LPCB approved.

Menvier Call Point addressable CBG 370S
Menvier Call Point addressable CBG 370S

Defender DC8S Mechanical Kitchen Suppression System
Defender DC8S Mechanical Kitchen Suppression System

Defender DPSS Pneumatic Kitchen Suppression System
Defender DPSS Pneumatic Kitchen Suppression System
4 Flows

Hochiki Conventional Wall Sounder
Hochiki Conventional Wall Sounder

CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)
CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)

C-Tec Conventional Manual Call Point
C-Tec Conventional Manual Call Point

C-Tec Addressable Heat Detector
C-Tec Addressable Heat Detector

C-Tec Addressable Smoke Detector
C-Tec Addressable Smoke Detector

Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
- Meet both EN54-3 and EN54-23.
- Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
- Suitable for wall and ceiling mount applications.
- Providing 16 tones.
- Highly efficient LED technology
-
High-visibility 50 mm FR reflective tape
-
Triple trim design for enhanced visibility in low light
- Size: 75 x100mm / (Max.D*H)
- Weight: 400g
- Buzzer type: Continuous Sound 110dB
- Material: steel material and ABS
- resin Insulation resistance: 100MQ (at500VDC)
- voltage: 500VA0, 50 / 60Hz 1 minute
- Power reaches: 40W
- Protection level: IP44
- Cable Type: Fire Cable
- Wire Gauge: 1.5mm
- Core Configuration: 2 cores
- Length: 100 meters
- Purpose: Specifically designed for fire alarm and detection systems, emergency lighting, and other fire safety applications.
- Fire Resistance: Constructed with materials that provide high fire resistance, ensuring reliable performance and maintaining the integrity of the cable during fire incidents.
- Product: 4 wire LPG gas detector
- Brand: Asenware
- Model Number: AW-D132C-4W
- Power Consumption: ≤2W @Alarm
- Alarm Horn: ≥ 85dB @3m
- Main Voltage: 24V DC
- Alarm Outputs: DC12V pulse voltage and Relay( COM ,NO )
- Warm Up Time: Approximately 90 Seconds
- Size: 104.5mm* 58mm* 29.1mm
- Weight: About 62g
- Conventional Manual Call Point Appearance
- LED Indicator
- Conventional Manual Call Point Working Environment
- This conventional manual call point is suitable for indoor use, in order to better achieve product performance.
- This conventional manual call point complies with the EN54-11 standard
- Soft addressed
- Integral short circuit isolator
- Single address
- Fast fit clip on front cover
- High visibility status LED
- Wide range of accessories
- Heavy duty terminals
- 8 Flow
- DC8 Cylinder + Valve + Activation Mechanism (1 Piece )
- DC8 Wall Mount Bracket (1 Piece )
- Remote Pull Station (1 Piece )
- A Nozzle (6 Piece)
- F Nozzle (1 Piece)
- 182°C ThermoBulb Detector Set (1 Piece )
- Corner Pulley (3 Piece )
- Cylinder + Wet Chemical (1 Piece )
- Wall Mount Bracket (1 Piece)
- Pneumatic Valve (1 Piece )
- Pneumatic Manuel Activation Button (1 Piece)
- Discharge Hose (1 Piece)
- A Nozzle (1 Piece)
- F Nozzle (1 Piece)
- R Nozzle (1 Piece)
- Detection Tube (6×1 mm) (10 meters)
- Robust design
- Low current consumption
- Easy to install
- Maximum 110dB(A) at 1 metre (dependant on tone selected)
- 32 user-selectable tones
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc = 3.8mA.
- IP33C rated.
- Certified to EN54 Parts 11 (LPCB) and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
- A high-quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
- Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. The default setting is A2.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- A high-quality smoke detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
- Smart algorithms help reduce false alarms.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Drift compensation functionality.
- 0.16dB/m sensitivity/obscuration level.
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- 8 zones panels
- Flexible, high specification system
- Surface or semi-flush mounting
- Simple “one-shot” auto-reset user test facility
- Maintenance free poly switch circuit protection, with auto reset
- Class change and programmable fire/fault relay as standard

Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)
Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)

Fire Beaters
Fire Beaters
A fire beater is a simple firefighting tool designed to suppress small fires by smothering flames and cutting off the oxygen supply. It is commonly used for controlling grass fires, bush fires, and small outdoor fires in farms, forests, and open areas

Firefighter Protective Suit (Fireman Suit)
Firefighter Protective Suit (Fireman Suit)
The firefighter suit is designed to provide maximum protection for professionals during firefighting operations. Designed to withstand extreme conditions, this suit delivers outstanding performance and comfort while combining style and durability.
Visibility & Safety

Fireman Gloves
Fireman Gloves
Fireman gloves are specially designed to protect firefighters and emergency responders from extreme heat, flames, sharp objects, and hazardous environments.


CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/1NC/1COM offers a crucial interface for residents to alert others in case of a fire or emergency to initiate the evacuation of a building, discharge gas, or open a controlled door.

SNG190 Siren
SNG190 Siren

IFS 1.5mm 2 core Fire Cable 100m full copper
IFS 1.5mm 2 core Fire Cable 100m full copper

Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh12,000.00
Asenware Conventional Manual Call Point AW-D135C
Asenware Conventional Manual Call Point AW-D135C

Asenware Conventional Smoke Detector AW-CSD381
Asenware Conventional Smoke Detector AW-CSD381
Model No. : AW-CSD381
Photo-Electric type spot detector
Built in dual LEDs
Visible from all around 360°
Remote indicator output
Compatible with most brands fire alarm panels.
LPCB approved.

Menvier Call Point addressable CBG 370S
Menvier Call Point addressable CBG 370S

Defender DC8S Mechanical Kitchen Suppression System
Defender DC8S Mechanical Kitchen Suppression System

Defender DPSS Pneumatic Kitchen Suppression System
Defender DPSS Pneumatic Kitchen Suppression System
4 Flows

Hochiki Conventional Wall Sounder
Hochiki Conventional Wall Sounder

CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)
CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)

C-Tec Conventional Manual Call Point
C-Tec Conventional Manual Call Point

C-Tec Addressable Heat Detector
C-Tec Addressable Heat Detector

C-Tec Addressable Smoke Detector
C-Tec Addressable Smoke Detector

Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
- Meet both EN54-3 and EN54-23.
- Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
- Suitable for wall and ceiling mount applications.
- Providing 16 tones.
- Highly efficient LED technology
-
High-visibility 50 mm FR reflective tape
-
Triple trim design for enhanced visibility in low light
- Size: 75 x100mm / (Max.D*H)
- Weight: 400g
- Buzzer type: Continuous Sound 110dB
- Material: steel material and ABS
- resin Insulation resistance: 100MQ (at500VDC)
- voltage: 500VA0, 50 / 60Hz 1 minute
- Power reaches: 40W
- Protection level: IP44
- Cable Type: Fire Cable
- Wire Gauge: 1.5mm
- Core Configuration: 2 cores
- Length: 100 meters
- Purpose: Specifically designed for fire alarm and detection systems, emergency lighting, and other fire safety applications.
- Fire Resistance: Constructed with materials that provide high fire resistance, ensuring reliable performance and maintaining the integrity of the cable during fire incidents.
- Product: 4 wire LPG gas detector
- Brand: Asenware
- Model Number: AW-D132C-4W
- Power Consumption: ≤2W @Alarm
- Alarm Horn: ≥ 85dB @3m
- Main Voltage: 24V DC
- Alarm Outputs: DC12V pulse voltage and Relay( COM ,NO )
- Warm Up Time: Approximately 90 Seconds
- Size: 104.5mm* 58mm* 29.1mm
- Weight: About 62g
- Conventional Manual Call Point Appearance
- LED Indicator
- Conventional Manual Call Point Working Environment
- This conventional manual call point is suitable for indoor use, in order to better achieve product performance.
- This conventional manual call point complies with the EN54-11 standard
- Soft addressed
- Integral short circuit isolator
- Single address
- Fast fit clip on front cover
- High visibility status LED
- Wide range of accessories
- Heavy duty terminals
- 8 Flow
- DC8 Cylinder + Valve + Activation Mechanism (1 Piece )
- DC8 Wall Mount Bracket (1 Piece )
- Remote Pull Station (1 Piece )
- A Nozzle (6 Piece)
- F Nozzle (1 Piece)
- 182°C ThermoBulb Detector Set (1 Piece )
- Corner Pulley (3 Piece )
- Cylinder + Wet Chemical (1 Piece )
- Wall Mount Bracket (1 Piece)
- Pneumatic Valve (1 Piece )
- Pneumatic Manuel Activation Button (1 Piece)
- Discharge Hose (1 Piece)
- A Nozzle (1 Piece)
- F Nozzle (1 Piece)
- R Nozzle (1 Piece)
- Detection Tube (6×1 mm) (10 meters)
- Robust design
- Low current consumption
- Easy to install
- Maximum 110dB(A) at 1 metre (dependant on tone selected)
- 32 user-selectable tones
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc = 3.8mA.
- IP33C rated.
- Certified to EN54 Parts 11 (LPCB) and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
- A high-quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
- Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. The default setting is A2.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- A high-quality smoke detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
- Smart algorithms help reduce false alarms.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Drift compensation functionality.
- 0.16dB/m sensitivity/obscuration level.
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
- 8 zones panels
- Flexible, high specification system
- Surface or semi-flush mounting
- Simple “one-shot” auto-reset user test facility
- Maintenance free poly switch circuit protection, with auto reset
- Class change and programmable fire/fault relay as standard

Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)
Asenware Addressable Fire Alarm Strobe Sounder Beacon (AW-D306)

Fire Beaters
Fire Beaters
A fire beater is a simple firefighting tool designed to suppress small fires by smothering flames and cutting off the oxygen supply. It is commonly used for controlling grass fires, bush fires, and small outdoor fires in farms, forests, and open areas

Firefighter Protective Suit (Fireman Suit)
Firefighter Protective Suit (Fireman Suit)
The firefighter suit is designed to provide maximum protection for professionals during firefighting operations. Designed to withstand extreme conditions, this suit delivers outstanding performance and comfort while combining style and durability.
Visibility & Safety

Fireman Gloves
Fireman Gloves
Fireman gloves are specially designed to protect firefighters and emergency responders from extreme heat, flames, sharp objects, and hazardous environments.


CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/ 1NC/ 1COM
CA-A002A Resettable Manual Call Point with Cover – 1N0/1NC/1COM offers a crucial interface for residents to alert others in case of a fire or emergency to initiate the evacuation of a building, discharge gas, or open a controlled door.

SNG190 Siren
SNG190 Siren

IFS 1.5mm 2 core Fire Cable 100m full copper
IFS 1.5mm 2 core Fire Cable 100m full copper

Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire
Asenware Conventional LPG Gas Detector AW-D132C-4W 24V DC 4 wire

Asenware Conventional Manual Call Point AW-D135C
Asenware Conventional Manual Call Point AW-D135C

Asenware Conventional Smoke Detector AW-CSD381
Asenware Conventional Smoke Detector AW-CSD381
Model No. : AW-CSD381
Photo-Electric type spot detector
Built in dual LEDs
Visible from all around 360°
Remote indicator output
Compatible with most brands fire alarm panels.
LPCB approved.

Menvier Call Point addressable CBG 370S
Menvier Call Point addressable CBG 370S

Defender DC8S Mechanical Kitchen Suppression System
Defender DC8S Mechanical Kitchen Suppression System

Defender DPSS Pneumatic Kitchen Suppression System
Defender DPSS Pneumatic Kitchen Suppression System
4 Flows

Hochiki Conventional Wall Sounder
Hochiki Conventional Wall Sounder

CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)
CTEC Conventional Hi-Output 100dB(A) Wall Sounder (deep base)

C-Tec Conventional Manual Call Point
C-Tec Conventional Manual Call Point

C-Tec Addressable Heat Detector
C-Tec Addressable Heat Detector

C-Tec Addressable Smoke Detector
C-Tec Addressable Smoke Detector

