- Fire Assembly Point Sign
- Fire Safety
- DIN rail mounting option
- Surface mounting option
- Plug in connectors
- Tri-colour LED status indication
- Address selector switches visible in 2 planes
- LED status visible in 2 planes
- Approved to GEA GEI 1-082 and CEA GEI 1-084
- Rotating Parabolic Reflector: For enhanced visibility from a distance.
- Extended Bulb Life: Vibration-resistant automobile bulb.
- Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
- Dome: Superior weather resistant and light translucent acrylic resin.
- Compliance: For 12V DC, 24V DC type only.
- Colors: Red
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Detector manufacturer approved
- Designed for use with the Solo 330/332 dispensers
- Non-toxic
- Silicone free
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3 zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3 conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8 flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort & hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.
KSh1,800.00 Excl. VAT
Fire Assembly Point (A3)
SKU: 624Fire Assembly Point (A3)
Made of Mountable all weather Aluco Board material and vinyl branding
Shop now at informedstore.co.ke or call +254 793 000 111
KSh14,000.00 Excl. VAT
Fire Alarm Loop Isolation Module
SKU: 597Fire Alarm Loop Isolation Module
KSh1,000.00 Excl. VAT
Rotary AC Warning Light
SKU: N/ARotary AC Warning Light
Warning lights are used to send a signal to neighbors when in danger.
KSh450,000.00 Excl. VAT
FM-200™ Fire Suppression Systems 80L
SKU: N/AFM-200™, also commonly known as HFC-227ea, is a clean agent fire suppressant for Class A, B, and C fires and meets NFPA Standard 2001 Clean Agent Fire Extinguishing Systems. Clean agents are fast and effective in suppressing fires, are safe in occupied spaces, and do not leave a residue.
KSh130,000.00 Excl. VAT
Ctec Fire Alarm Control Panel 2 loop Addressable Panel
SKU: 20A12DDS10D0031 072PCtec Fire Alarm Control Panel 2 loop Addressable Panel
KSh92,000.00 Excl. VAT
Ctec 1 Loop Addressable Fire Panel
SKU: N/ACtec 1 Loop Addressable Fire Panel
KSh2,500.00 Excl. VAT
Asenware sounder and flasher
SKU: N/AAsenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya
KSh1,200.00 Asenware Convectional heat detector AW-CTD382
SKU: N/A
KSh9,500.00 Excl. VAT
A5 Solo Smoke Detector Tester 125ml
SKU: N/AA5 Solo Smoke Detector Tester 125ml
All Solo smoke aerosols are:
KSh87,000.00 Excl. VAT
Ctec EP203 Automatic Extinguisher Panel
SKU: N/ACtec EP203 Automatic Extinguisher Panel
KSh22,000.00 INIM Conventional control panel with 4 zones expandable to 20
SKU: N/AINIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).
KSh18,000.00 Non-expandable 2 zone conventional control panel – SmartLine020-2
SKU: N/ASmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).
KSh45,000.00 Excl. VAT
C-TEC Standard 8 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 8 Zone Conventional Fire Alarm Panel
KSh35,000.00 Excl. VAT
C-TEC Standard 4 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 4 Zone Conventional Fire Alarm Panel
KSh25,000.00 Excl. VAT
Asenware 8 Zone Fire alarm control Panel
SKU: N/AAsenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
KSh18,000.00 Excl. VAT
Asenware 4 Zone Fire Alarm Control Panel
SKU: N/AAsenware 4 Zone Fire Alarm Control Panel
KSh1,500.00 Excl. VAT
Break Glass Fire Emergency Door Release Red (CA-A001A)
SKU: N/ABreak Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places
KSh3,500.00 Excl. VAT
Inim conventional Manual Call Point
SKU: N/AInim conventional Manual Call Point
KSh6,500.00 Excl. VAT
Conventional Sounder with Flasher
SKU: N/AConventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level
KSh1,900.00 AW-CTD321 Conventional Fix Temperature Heat Detector
SKU: N/AConventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
- Fire Assembly Point Sign
- Fire Safety
- DIN rail mounting option
- Surface mounting option
- Plug in connectors
- Tri-colour LED status indication
- Address selector switches visible in 2 planes
- LED status visible in 2 planes
- Approved to GEA GEI 1-082 and CEA GEI 1-084
- Rotating Parabolic Reflector: For enhanced visibility from a distance.
- Extended Bulb Life: Vibration-resistant automobile bulb.
- Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
- Dome: Superior weather resistant and light translucent acrylic resin.
- Compliance: For 12V DC, 24V DC type only.
- Colors: Red
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Detector manufacturer approved
- Designed for use with the Solo 330/332 dispensers
- Non-toxic
- Silicone free
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3 zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3 conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8 flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort & hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.

Fire Assembly Point (A3)
Fire Assembly Point (A3)
Made of Mountable all weather Aluco Board material and vinyl branding
Shop now at informedstore.co.ke or call +254 793 000 111

Fire Alarm Loop Isolation Module
Fire Alarm Loop Isolation Module

Rotary AC Warning Light
Rotary AC Warning Light
Warning lights are used to send a signal to neighbors when in danger.

FM-200™ Fire Suppression Systems 80L
FM-200™, also commonly known as HFC-227ea, is a clean agent fire suppressant for Class A, B, and C fires and meets NFPA Standard 2001 Clean Agent Fire Extinguishing Systems. Clean agents are fast and effective in suppressing fires, are safe in occupied spaces, and do not leave a residue.

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

A5 Solo Smoke Detector Tester 125ml
A5 Solo Smoke Detector Tester 125ml
All Solo smoke aerosols are:

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
- Fire Assembly Point Sign
- Fire Safety
- DIN rail mounting option
- Surface mounting option
- Plug in connectors
- Tri-colour LED status indication
- Address selector switches visible in 2 planes
- LED status visible in 2 planes
- Approved to GEA GEI 1-082 and CEA GEI 1-084
- Rotating Parabolic Reflector: For enhanced visibility from a distance.
- Extended Bulb Life: Vibration-resistant automobile bulb.
- Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
- Dome: Superior weather resistant and light translucent acrylic resin.
- Compliance: For 12V DC, 24V DC type only.
- Colors: Red
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Detector manufacturer approved
- Designed for use with the Solo 330/332 dispensers
- Non-toxic
- Silicone free
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3 zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3 conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8 flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort & hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.

Fire Assembly Point (A3)
Fire Assembly Point (A3)
Made of Mountable all weather Aluco Board material and vinyl branding
Shop now at informedstore.co.ke or call +254 793 000 111

Fire Alarm Loop Isolation Module
Fire Alarm Loop Isolation Module

Rotary AC Warning Light
Rotary AC Warning Light
Warning lights are used to send a signal to neighbors when in danger.

FM-200™ Fire Suppression Systems 80L
FM-200™, also commonly known as HFC-227ea, is a clean agent fire suppressant for Class A, B, and C fires and meets NFPA Standard 2001 Clean Agent Fire Extinguishing Systems. Clean agents are fast and effective in suppressing fires, are safe in occupied spaces, and do not leave a residue.

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

A5 Solo Smoke Detector Tester 125ml
A5 Solo Smoke Detector Tester 125ml
All Solo smoke aerosols are:

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
- Fire Assembly Point Sign
- Fire Safety
- DIN rail mounting option
- Surface mounting option
- Plug in connectors
- Tri-colour LED status indication
- Address selector switches visible in 2 planes
- LED status visible in 2 planes
- Approved to GEA GEI 1-082 and CEA GEI 1-084
- Rotating Parabolic Reflector: For enhanced visibility from a distance.
- Extended Bulb Life: Vibration-resistant automobile bulb.
- Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
- Dome: Superior weather resistant and light translucent acrylic resin.
- Compliance: For 12V DC, 24V DC type only.
- Colors: Red
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power interruption.
- Detector manufacturer approved
- Designed for use with the Solo 330/332 dispensers
- Non-toxic
- Silicone free
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3 zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3 conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8 flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort & hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Manual callpoint with resettable element operated by plastic key (included).
- Warning flag and LED confirmation of activation.
- Selectable resistance.

Fire Assembly Point (A3)
Fire Assembly Point (A3)
Made of Mountable all weather Aluco Board material and vinyl branding
Shop now at informedstore.co.ke or call +254 793 000 111

Fire Alarm Loop Isolation Module
Fire Alarm Loop Isolation Module

Rotary AC Warning Light
Rotary AC Warning Light
Warning lights are used to send a signal to neighbors when in danger.

FM-200™ Fire Suppression Systems 80L
FM-200™, also commonly known as HFC-227ea, is a clean agent fire suppressant for Class A, B, and C fires and meets NFPA Standard 2001 Clean Agent Fire Extinguishing Systems. Clean agents are fast and effective in suppressing fires, are safe in occupied spaces, and do not leave a residue.

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

A5 Solo Smoke Detector Tester 125ml
A5 Solo Smoke Detector Tester 125ml
All Solo smoke aerosols are:

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

Non-expandable 2 zone conventional control panel – SmartLine020-2
SmartLine020-2
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4), and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

Break Glass Fire Emergency Door Release Red (CA-A001A)
Break Glass Fire Emergency Door Release Red (CA-A001A)
Supports electrical control or access control system
-Made of durable plastic shell and easy to install
-Use the Fireproof Material, Accord with the Safe Reques
-Sandblast Panel with Elegant Style
-Eyewitness only need to broke face-plate glass of conflagration Security Alarm Button in strength, then can make conflagration signal sending to the controller and give out the part of conflagration.
-Best protector in home, shop and other places

Inim conventional Manual Call Point
Inim conventional Manual Call Point

Conventional Sounder with Flasher
Conventional Sounder with Flasher
Acoustic and visual alarm indicator approved according new EN54-23 standard, IP65 protection rated (deep base version only), Operating voltage from 17 to 60 Vdc, mounting base included.
Selectable tone among 32 available by means of DIP SWITCH, flashing frequency selectable at 0,5Hz / 1Hz (by means of DIP SWITCH), 2 selectable sound level

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
