- Red Call Point
- 470 Ohm
- No LED
- Resettable plate insert
- Surface mount
- 87 x 87 x 53mm
- MX004: Resettable plate insert replacements (pack of 10)
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- Two Loop Control Panel, 230Vac, 2 sounder circuits.
- Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels or any mix up to max 16 loops)
- True peer-to-peer and fault tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Available in 1, 2 and 4 loop versions
- Up to 200 addresses per loop
- Full network capability up to 126 panels
- Event History Buffer (9,999 events) with Date/Time stamp
- Soft addressing
- Large versatile touch screen user interface
- Multi-language selection capability
- Integral printer (optional)
- Integral battery and power supply
- Flexible cause and effect programming
- Simple to operate end user touch-screen interface
- Flexible distributed network capability
- Full range of compatible accessories
- Easy to design system cause and effect using site installer software
- Full system integrity with Eaton’s managed protocol
- Integral Printer, Network Card
- Conventional Detectors
- LED Light
- Low-profile design
- White
- Dimensions 100mm x 43mm
- CE marked
- Indoor use
- Requires Menvier Base
- Four programmable separate detection
- capabilities within one unit
- Can be programmed to activate at 60°C or 77°C reducing the potential for false alarms
- Conventional Fire 10V-30V Operation
- 12V/4-wire Operation With Alarm Relay: 4W
- Suitable for fast fire detection where normal temperatures do not exceed 38°C
- Unsuitable for environments where the temperature may change rapidly
- Microprocessor Technology
- Digital Technology Detection Algorithms
- Latch Input Enables Auto Reset: 4W
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- The detector is Kitchen Platform Panel mountable.
- More effective than competing Products in terms of the ability to detect LPG/PNG
- More effective than competing Products in terms of the ability to detect LPG/PNG
- 1, 2 and 4 loop versions
- Spur tolerant soft addressing
- Full network capability
- Optional integral printer
- Integral battery and power supply
- 200 addresses per loop
- Charger with temperature compensation built in
- Checks battery capacity
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Inim ED100 Optical Smoke Detector
SKU: N/AED100
Optical smoke detector
The ED100 optical smoke detector is based on the Tyndall effect (diffusion of light) and provides firstrate early warning in the event of fire.
It offers wide-spectrum detection of smoke particles generated by the majority of fires. The newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen ensure high immunity to false alarms.
The sensitivity can be configured to suit a wide range of applications (sensitivity configurable as: 0.08dB/m; 0.10dB/m; 0.12dB/m; 0.15dB/m).

Weather Proof Conventional Fire Strobe Sounder
SKU: N/AWeather-proof conventional fire strobe sounder is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.

RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)
SKU: 804RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)

ASENWATRE 2 Zone Conventional Fire Panel
SKU: 821ASENWATRE 2 Zone Conventional Fire Panel

2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS
SKU: 10122 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS

Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
SKU: 1010Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Sounder Beacon
SKU: 1008Informed Systems Menvier Sounder Beacon in Nairobi Kenya has the below features and Benefits.
Key Features
32 tones (user selectable)
12V or 24V
Secure clip-fit base
Volume control
Fire-approved and Signalling tone options
For Fire, Security, and Signalling
Quick fitting for easy installation
Reduce output to suit the application
Benefits
Up to 103dB(A) with built-in Xenon flash
Suitable for a variety of application
Improved tone clarity, reducing confusion

Menvier Addressable Manual Call Point
SKU: 1007Menvier Addressable Manual Call Point
Available in indoor and outdoor options, the call point can also be either surface mounted using the rear BESA fixing or recessed mounted with the addition of recessing bezels sold separately.
Alongside the recessing bezels, a comprehensive range of accessories can be used with Informed System Ltd’s addressable fire system call point including protective hinge covers for busy areas, spacer plates, resettable element kit, and spare glass in packs of 5 pieces.
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Smoke Detector
SKU: 1006Menvier Smoke Detector
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Heat Detector
SKU: 1005Menvier Heat Detector

CTEC Conventional Photoelectric Smoke Detector
SKU: 939CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
SKU: 938CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
SKU: 937CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
SKU: 935Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

220V STANDALONE LPG GAS DETECTOR
SKU: 926220V STANDALONE LPG GAS DETECTOR

ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
SKU: 924ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
Asenware Standalone Battery Smoke detector is a photodetector that uses the most advanced optical sensing chamber. The detector is designed to provide open area protection.

Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
SKU: 923Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler

menvier 1 loop panel
SKU: 1038menvier 1 loop panel

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
SKU: N/ACtec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
SKU: N/ACtec 1 Loop Addressable Fire Panel
- Red Call Point
- 470 Ohm
- No LED
- Resettable plate insert
- Surface mount
- 87 x 87 x 53mm
- MX004: Resettable plate insert replacements (pack of 10)
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- Two Loop Control Panel, 230Vac, 2 sounder circuits.
- Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels or any mix up to max 16 loops)
- True peer-to-peer and fault tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Available in 1, 2 and 4 loop versions
- Up to 200 addresses per loop
- Full network capability up to 126 panels
- Event History Buffer (9,999 events) with Date/Time stamp
- Soft addressing
- Large versatile touch screen user interface
- Multi-language selection capability
- Integral printer (optional)
- Integral battery and power supply
- Flexible cause and effect programming
- Simple to operate end user touch-screen interface
- Flexible distributed network capability
- Full range of compatible accessories
- Easy to design system cause and effect using site installer software
- Full system integrity with Eaton’s managed protocol
- Integral Printer, Network Card
- Conventional Detectors
- LED Light
- Low-profile design
- White
- Dimensions 100mm x 43mm
- CE marked
- Indoor use
- Requires Menvier Base
- Four programmable separate detection
- capabilities within one unit
- Can be programmed to activate at 60°C or 77°C reducing the potential for false alarms
- Conventional Fire 10V-30V Operation
- 12V/4-wire Operation With Alarm Relay: 4W
- Suitable for fast fire detection where normal temperatures do not exceed 38°C
- Unsuitable for environments where the temperature may change rapidly
- Microprocessor Technology
- Digital Technology Detection Algorithms
- Latch Input Enables Auto Reset: 4W
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- The detector is Kitchen Platform Panel mountable.
- More effective than competing Products in terms of the ability to detect LPG/PNG
- More effective than competing Products in terms of the ability to detect LPG/PNG
- 1, 2 and 4 loop versions
- Spur tolerant soft addressing
- Full network capability
- Optional integral printer
- Integral battery and power supply
- 200 addresses per loop
- Charger with temperature compensation built in
- Checks battery capacity
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Inim ED100 Optical Smoke Detector
ED100
Optical smoke detector
The ED100 optical smoke detector is based on the Tyndall effect (diffusion of light) and provides firstrate early warning in the event of fire.
It offers wide-spectrum detection of smoke particles generated by the majority of fires. The newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen ensure high immunity to false alarms.
The sensitivity can be configured to suit a wide range of applications (sensitivity configurable as: 0.08dB/m; 0.10dB/m; 0.12dB/m; 0.15dB/m).

Weather Proof Conventional Fire Strobe Sounder
Weather-proof conventional fire strobe sounder is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.

RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)
RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS
2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS

Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Sounder Beacon
Informed Systems Menvier Sounder Beacon in Nairobi Kenya has the below features and Benefits.
Key Features
32 tones (user selectable)
12V or 24V
Secure clip-fit base
Volume control
Fire-approved and Signalling tone options
For Fire, Security, and Signalling
Quick fitting for easy installation
Reduce output to suit the application
Benefits
Up to 103dB(A) with built-in Xenon flash
Suitable for a variety of application
Improved tone clarity, reducing confusion

Menvier Addressable Manual Call Point
Menvier Addressable Manual Call Point
Available in indoor and outdoor options, the call point can also be either surface mounted using the rear BESA fixing or recessed mounted with the addition of recessing bezels sold separately.
Alongside the recessing bezels, a comprehensive range of accessories can be used with Informed System Ltd’s addressable fire system call point including protective hinge covers for busy areas, spacer plates, resettable element kit, and spare glass in packs of 5 pieces.
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Smoke Detector
Menvier Smoke Detector
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Heat Detector
Menvier Heat Detector

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

220V STANDALONE LPG GAS DETECTOR
220V STANDALONE LPG GAS DETECTOR

ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
Asenware Standalone Battery Smoke detector is a photodetector that uses the most advanced optical sensing chamber. The detector is designed to provide open area protection.

Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler

menvier 1 loop panel
menvier 1 loop panel

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel
- Red Call Point
- 470 Ohm
- No LED
- Resettable plate insert
- Surface mount
- 87 x 87 x 53mm
- MX004: Resettable plate insert replacements (pack of 10)
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- Two Loop Control Panel, 230Vac, 2 sounder circuits.
- Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels or any mix up to max 16 loops)
- True peer-to-peer and fault tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Available in 1, 2 and 4 loop versions
- Up to 200 addresses per loop
- Full network capability up to 126 panels
- Event History Buffer (9,999 events) with Date/Time stamp
- Soft addressing
- Large versatile touch screen user interface
- Multi-language selection capability
- Integral printer (optional)
- Integral battery and power supply
- Flexible cause and effect programming
- Simple to operate end user touch-screen interface
- Flexible distributed network capability
- Full range of compatible accessories
- Easy to design system cause and effect using site installer software
- Full system integrity with Eaton’s managed protocol
- Integral Printer, Network Card
- Conventional Detectors
- LED Light
- Low-profile design
- White
- Dimensions 100mm x 43mm
- CE marked
- Indoor use
- Requires Menvier Base
- Four programmable separate detection
- capabilities within one unit
- Can be programmed to activate at 60°C or 77°C reducing the potential for false alarms
- Conventional Fire 10V-30V Operation
- 12V/4-wire Operation With Alarm Relay: 4W
- Suitable for fast fire detection where normal temperatures do not exceed 38°C
- Unsuitable for environments where the temperature may change rapidly
- Microprocessor Technology
- Digital Technology Detection Algorithms
- Latch Input Enables Auto Reset: 4W
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- The detector is Kitchen Platform Panel mountable.
- More effective than competing Products in terms of the ability to detect LPG/PNG
- More effective than competing Products in terms of the ability to detect LPG/PNG
- 1, 2 and 4 loop versions
- Spur tolerant soft addressing
- Full network capability
- Optional integral printer
- Integral battery and power supply
- 200 addresses per loop
- Charger with temperature compensation built in
- Checks battery capacity
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Inim ED100 Optical Smoke Detector
ED100
Optical smoke detector
The ED100 optical smoke detector is based on the Tyndall effect (diffusion of light) and provides firstrate early warning in the event of fire.
It offers wide-spectrum detection of smoke particles generated by the majority of fires. The newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen ensure high immunity to false alarms.
The sensitivity can be configured to suit a wide range of applications (sensitivity configurable as: 0.08dB/m; 0.10dB/m; 0.12dB/m; 0.15dB/m).

Weather Proof Conventional Fire Strobe Sounder
Weather-proof conventional fire strobe sounder is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.

RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)
RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS
2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS

Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Sounder Beacon
Informed Systems Menvier Sounder Beacon in Nairobi Kenya has the below features and Benefits.
Key Features
32 tones (user selectable)
12V or 24V
Secure clip-fit base
Volume control
Fire-approved and Signalling tone options
For Fire, Security, and Signalling
Quick fitting for easy installation
Reduce output to suit the application
Benefits
Up to 103dB(A) with built-in Xenon flash
Suitable for a variety of application
Improved tone clarity, reducing confusion

Menvier Addressable Manual Call Point
Menvier Addressable Manual Call Point
Available in indoor and outdoor options, the call point can also be either surface mounted using the rear BESA fixing or recessed mounted with the addition of recessing bezels sold separately.
Alongside the recessing bezels, a comprehensive range of accessories can be used with Informed System Ltd’s addressable fire system call point including protective hinge covers for busy areas, spacer plates, resettable element kit, and spare glass in packs of 5 pieces.
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Smoke Detector
Menvier Smoke Detector
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Heat Detector
Menvier Heat Detector

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

220V STANDALONE LPG GAS DETECTOR
220V STANDALONE LPG GAS DETECTOR

ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
Asenware Standalone Battery Smoke detector is a photodetector that uses the most advanced optical sensing chamber. The detector is designed to provide open area protection.

Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler

menvier 1 loop panel
menvier 1 loop panel

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel
- Red Call Point
- 470 Ohm
- No LED
- Resettable plate insert
- Surface mount
- 87 x 87 x 53mm
- MX004: Resettable plate insert replacements (pack of 10)
- It has 2 level control mode with a lock
- It has a SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has an optional GSM module for fire alarms by SMS.
- Two Loop Control Panel, 230Vac, 2 sounder circuits.
- Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels or any mix up to max 16 loops)
- True peer-to-peer and fault tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
- Available in 1, 2 and 4 loop versions
- Up to 200 addresses per loop
- Full network capability up to 126 panels
- Event History Buffer (9,999 events) with Date/Time stamp
- Soft addressing
- Large versatile touch screen user interface
- Multi-language selection capability
- Integral printer (optional)
- Integral battery and power supply
- Flexible cause and effect programming
- Simple to operate end user touch-screen interface
- Flexible distributed network capability
- Full range of compatible accessories
- Easy to design system cause and effect using site installer software
- Full system integrity with Eaton’s managed protocol
- Integral Printer, Network Card
- Conventional Detectors
- LED Light
- Low-profile design
- White
- Dimensions 100mm x 43mm
- CE marked
- Indoor use
- Requires Menvier Base
- Four programmable separate detection
- capabilities within one unit
- Can be programmed to activate at 60°C or 77°C reducing the potential for false alarms
- Conventional Fire 10V-30V Operation
- 12V/4-wire Operation With Alarm Relay: 4W
- Suitable for fast fire detection where normal temperatures do not exceed 38°C
- Unsuitable for environments where the temperature may change rapidly
- Microprocessor Technology
- Digital Technology Detection Algorithms
- Latch Input Enables Auto Reset: 4W
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- A high quality Type CS static high temperature heat detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
- Key box for the secure but accessible storage of emergency door keys
- Snatch-off plastic window is easy to open in an emergency – no need for a hammer
- Replacement windows are available
- Ideal for food preparation areas, clean rooms, swimming pools, etc.
- Available in red or green
- Also available featuring integral electronic alarm (85db)
- The detector is Kitchen Platform Panel mountable.
- More effective than competing Products in terms of the ability to detect LPG/PNG
- More effective than competing Products in terms of the ability to detect LPG/PNG
- 1, 2 and 4 loop versions
- Spur tolerant soft addressing
- Full network capability
- Optional integral printer
- Integral battery and power supply
- 200 addresses per loop
- Charger with temperature compensation built in
- Checks battery capacity
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Inim ED100 Optical Smoke Detector
ED100
Optical smoke detector
The ED100 optical smoke detector is based on the Tyndall effect (diffusion of light) and provides firstrate early warning in the event of fire.
It offers wide-spectrum detection of smoke particles generated by the majority of fires. The newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen ensure high immunity to false alarms.
The sensitivity can be configured to suit a wide range of applications (sensitivity configurable as: 0.08dB/m; 0.10dB/m; 0.12dB/m; 0.15dB/m).

Weather Proof Conventional Fire Strobe Sounder
Weather-proof conventional fire strobe sounder is powered by a 24v electrical circuit. In the event of a fire, the sounder will sound and flash at the same time. Very stable and reliable; easy to install and wire; can be used in different emergency situations.

RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)
RESETTABLE FIRE MANUAL CALL POINT RED (CA-A002R)

ASENWATRE 2 Zone Conventional Fire Panel
ASENWATRE 2 Zone Conventional Fire Panel

2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS
2 loop fire alarm panel -DXC2-LOOP REGION HONEYWELL MORLEY MORLEY-IAS

Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Cooper Menvier CF30002GPNC 2 Loop Addressable Control Panel c/w Integral Printer, Network Card
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Sounder Beacon
Informed Systems Menvier Sounder Beacon in Nairobi Kenya has the below features and Benefits.
Key Features
32 tones (user selectable)
12V or 24V
Secure clip-fit base
Volume control
Fire-approved and Signalling tone options
For Fire, Security, and Signalling
Quick fitting for easy installation
Reduce output to suit the application
Benefits
Up to 103dB(A) with built-in Xenon flash
Suitable for a variety of application
Improved tone clarity, reducing confusion

Menvier Addressable Manual Call Point
Menvier Addressable Manual Call Point
Available in indoor and outdoor options, the call point can also be either surface mounted using the rear BESA fixing or recessed mounted with the addition of recessing bezels sold separately.
Alongside the recessing bezels, a comprehensive range of accessories can be used with Informed System Ltd’s addressable fire system call point including protective hinge covers for busy areas, spacer plates, resettable element kit, and spare glass in packs of 5 pieces.
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Smoke Detector
Menvier Smoke Detector
Shop now at informedstore.co.ke or call +254 793 000 111

Menvier Heat Detector
Menvier Heat Detector

CTEC Conventional Photoelectric Smoke Detector
CTEC Conventional Photoelectric Smoke Detector

CTEC Conventional Heat Detector
CTEC Conventional Heat Detector

CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/
keyswitch entry.

Rectangular Sensored Keyguard
Rectangular Sensored Keyguard
Shop now at informedstore.co.ke or call +254 793 000 111

220V STANDALONE LPG GAS DETECTOR
220V STANDALONE LPG GAS DETECTOR

ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
ASENWARE STANDALONE BATTERY OPERATED SMOKE DETECTOR
Asenware Standalone Battery Smoke detector is a photodetector that uses the most advanced optical sensing chamber. The detector is designed to provide open area protection.

Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
Asenware 12-32 Zone Fire Alarm Control Panel AW-CFP2166-12-32
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler

menvier 1 loop panel
menvier 1 loop panel

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel