- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc
KSh290,000.00 Excl. VAT
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
SKU: 20A12DDS10D0031 084PCTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
KSh6,200.00 C-TEC CA470 Cast Addressable Manual Call Point
SKU: N/AC-Tec CA470 CAST Addressable Manual Call Point Features
KSh4,800.00 EC0011E Manual callpoint (IP67)
SKU: N/AEC0011E Manual callpoint for outdoor installation (IP67)
KSh15,000.00 Excl. VAT
Morley Honeywell Addressable Sounder with Flasher
SKU: N/AMorley Honeywell Addressable Sounder with Flasher
KSh8,400.00 ES2000 Addressable wall mount audible/visual-audible alarm indicator
SKU: N/AES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.
KSh15,000.00 Excl. VAT
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
SKU: N/AC-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23
KSh6,500.00 Excl. VAT
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
SKU: N/AMI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
KSh6,500.00 Excl. VAT
Apollo XP95 Ionisation Smoke Detector
SKU: N/AApollo XP95 Ionisation Smoke Detector
KSh15,000.00 Excl. VAT
2 Zone Fire Alarm Panel AW-CFP2166-2
SKU: N/A2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.
KSh2,750.00 Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
SKU: N/AHoneywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,750.00- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh4,800.00
Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh2,750.00- Certified to EN54 parts 2 and 4 by Intertek.
- Apollo XP95/Discovery protocol.
- Attractive 450 x 462 x 127mm cabinet (medium and large sized cabinets also available).
- Up to 4 loops per panel (6 to 8 loops available in medium and large sized cabinets).
- Up to 64 eight-loop peer to peer panel network capacity.
- Hi-integrity and singlepath networking options.
- Very flexible cause and effects.
- Wide range of Switch & Indicator modules.
- Multiple ‘A-Bus’ expansion PCBs (I/O Units, Relays, etc).
- User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.
- Up to 100 separate and programmable zonal LEDs (200 on medium and large sized cabinets).
- 10,000 programmable and indicatable detection zones.
- Up to 38 characters of custom text per loop device.
- Automatic daylight saving (BST/GMT) mode.
- 20,000 event memory (filterable by fire, fault & date).
- Non-fire supervisory event functionality.
- Optional thermal printers.
- Well-designed cabinets with easily removable electronics chassis.
- 20-way heavy-duty brass earth bar as standard.
- 72-hour standby ( 30 min alarm) in standard cabinets.
- Built-in loop status & current-reading.
- Powerful engineering and commissioning functions including SafeMode and DeviceManager.
- Attractive Compact Controllers.
- Wide range of flush-fit bezels and attractive glazed stainless steel frames
- FULLY compatible with C-TEC manufactured addressable ancillaries (Hush Buttons, Sounders, Voice Sounders and Beacons)
- Powerful and intuitive PC programming tools
- Wide range of supported languages
- A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
- Surface or flush mountable.
- Onboard short-circuit loop isolator.
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with reset/back box removal key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
- IP42 rated (IP67 rated version also available, order code CA47067)
- Yellow, green, blue and white versions also available.
- Addressable manual alarm button Enea;
- Operating temperature -30°C /+70°C
- Suitable for outdoor conditions IP67.
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by Intertek.
- Provides ‘W-3-3.1’ light distribution when wall mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘C-3-8’ light distribution when ceiling mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- Onboard short-circuit loop isolator.
- 550µA quiescent current.
- 14mA alarm current @24V DC (VAD lit, sounder on max).
- Group addressing facility allows multiple devices to be operated simultaneously.
- 7 selectable volume levels and up to 15 selectable tone pairs.
- IP21C rated.
- Manufacturer : Morley by Honeywell
- Part Number : MI-PSE-S2-IV
- Analogue Addressable Optical Smoke Detector
- Morley IAS Protocol
- Colour : Ivory
- Requires B501AP-IV Detector Base
- Fully compatible with C-TEC’s XFP & ZFP XP95/Discovery Addressable Fire Panels.
- Uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
- Responds well to fast-burning, flaming fires.
- Designed to operate in a variety of environments.
- Red LED illuminates when the detector is in alarm.
- Certified to EN54-7 by the LPCB.
- Requires a 45681-210APO standard base or 45681-242APO low power relay base.
- ‘Xpert’ card addressed for speedy installation.
- Plug and play – No need for any installation support
- Cable and wire free- No more headaches of following up electricians or installers
- Inbuilt alarm buzzer to notify use in case of fire
- Low operating cost- Just needs 2 AAA batteries
- Use it anywhere: Homes, offices, stores etc

CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL
CTEC 4 LOOP 2 ZONE ADDRESSABLE FIRE ALARM PANEL

C-TEC CA470 Cast Addressable Manual Call Point
C-Tec CA470 CAST Addressable Manual Call Point Features

EC0011E Manual callpoint (IP67)
EC0011E Manual callpoint for outdoor installation (IP67)

Morley Honeywell Addressable Sounder with Flasher
Morley Honeywell Addressable Sounder with Flasher

ES2000 Addressable wall mount audible/visual-audible alarm indicator
ES2000 Addressable wall mount audible/visual-audible alarm indicator
Wall mount addressable audible/visual-audible alarm indicator, IP65 protection rating.
Volume, flash intensity, and sound sequences can be selected via the control panel (and diversified in accordance with the situation) from the 14 tones and 16 voice messages available in 8 different languages on-board the device (only for versions with the voice function).*
For models with the voice function, it is also possible to customize tones/voice messages by means of the EITK2000.
The device is powered via the loop but is equipped with terminals for optional separate power input.

C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23 BF453A/CX/SR
C-TEC ADDRESSABLE CX VOICE SOUNDER & VAD BEACON – RED – EN54-3 & EN54-23

MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable
MI-PSE-S2-IV Morley Smoke Detector Optical Analogue Addressable

Apollo XP95 Ionisation Smoke Detector
Apollo XP95 Ionisation Smoke Detector

2 Zone Fire Alarm Panel AW-CFP2166-2
2 Zone Fire Alarm Panel AW-CFP2166
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Honeywell Standalone JTYJ-GD-2330/B Plastic Battery Operated Smoke Detector