- Certified to EN54 Part 11 & 17.
- Resettable operating element.
- Easy access front reset mechanism.
- Ergonomic reset key (supplied).
- 170° viewable LED.
- Continuity link for cable insulation testing.
- Suitable for semi flush or surface mounting.
- Combined sounder and beacon unit
- Supplied with built-in isolator
- Three selectable tones which comply with EN 54-3:2001
- Suitable for use as a fire alarm system indicator
- Wall mounted
- Weatherproof (IP65 rated)
- Volume control feature: adjustable sound output from 100dB to 92 dB
- Tone and flash synchronisation
- Designed to work with XFP and Kentec fire alarm panels
- Responds to its own individual address
- Can be group addressed – allows multiple sounders to be controlled simultaneously
- No external power supply needed
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and  to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature  changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power  interruption.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby
KSh5,000.00 Automatic Dry Powder 9KG
SKU: 39Automatic Dry Powder 9KG
Designed for fixed automatic protection. Suitable for Class A, B, C fire risks and electrical fires.
The 6kg automatic extinguisher will protect an area up to 20 cubic metres.
This Automatic Extinguisher can be used for the following applications: trucks, small boats, large boats, motor sports and engine/plant rooms.
Fully refillable stored pressure extinguisher, with 68ºC red bulb automatic sprinkler fitted as standard (other bulb temperatures available on request for bulk orders). Fitted with pressure gauge for routine inspection. Bracketry included with extinguisher.
KSh4,500.00 Excl. VAT
IFS 0.8 MM Fire Resistance Cable 100M Drum
SKU: 370.8mm Fire Resistance Cable 100M Drum
We supply a full range of Fire Resistance Cables and fire performance cables, often also referred to as fire survival cables, fireproof cables, or simply fire cables.It is designed to resist the spread of fire into a new area. Fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.
KSh7,500.00 Excl. VAT
Apollo Manual Addressable Call Point with Isolator – XP95
SKU: 20A12DDS10D0031 031PApollo Manual Addressable Call Point with Isolator – XP95
KSh20.00 Excl. VAT
Fire Extinguisher Safety Seal
SKU: 303Fire Extinguisher Safety Seal
Yellow Tamper Seals, Zip Ties for Fire Extinguishers and Fire Safety
KSh15,500.00 Excl. VAT
Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon
SKU: 20A12DDS10D0031 022PApollo XP95 Open Area Weatherproof Addressable Sounder Beacon
KSh130,000.00 Excl. VAT
Ctec Fire Alarm Control Panel 2 loop Addressable Panel
SKU: 20A12DDS10D0031 072PCtec Fire Alarm Control Panel 2 loop Addressable Panel
KSh92,000.00 Excl. VAT
Ctec 1 Loop Addressable Fire Panel
SKU: N/ACtec 1 Loop Addressable Fire Panel
KSh2,500.00 Excl. VAT
Asenware sounder and flasher
SKU: N/AAsenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya
KSh1,200.00 Asenware Convectional heat detector AW-CTD382
SKU: N/A
KSh87,000.00 Excl. VAT
Ctec EP203 Automatic Extinguisher Panel
SKU: N/ACtec EP203 Automatic Extinguisher Panel
KSh22,000.00 INIM Conventional control panel with 4 zones expandable to 20
SKU: N/AINIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).
KSh45,000.00 Excl. VAT
C-TEC Standard 8 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 8 Zone Conventional Fire Alarm Panel
KSh35,000.00 Excl. VAT
C-TEC Standard 4 Zone Conventional Fire Alarm Panel
SKU: N/AC-TEC Standard 4 Zone Conventional Fire Alarm Panel
KSh25,000.00 Excl. VAT
Asenware 8 Zone Fire alarm control Panel
SKU: N/AAsenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
KSh18,000.00 Excl. VAT
Asenware 4 Zone Fire Alarm Control Panel
SKU: N/AAsenware 4 Zone Fire Alarm Control Panel
KSh1,900.00 AW-CTD321 Conventional Fix Temperature Heat Detector
SKU: N/AConventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference
KSh1,200.00 Excl. VAT
Asenware Smoke Detector AW-CSD311
SKU: N/AAsenware Smoke Detector AW-CSD311
AW-CSD311Â is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
KSh1,900.00 Inim Conventional Heat Detector ID200
SKU: N/AInim Conventional Heat Detector ID200
KSh1,500.00 Conventional Optical smoke detector
SKU: N/AConventional Optical smoke detector
KSh240,000.00 Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
SKU: N/AMorley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
- Certified to EN54 Part 11 & 17.
- Resettable operating element.
- Easy access front reset mechanism.
- Ergonomic reset key (supplied).
- 170° viewable LED.
- Continuity link for cable insulation testing.
- Suitable for semi flush or surface mounting.
- Combined sounder and beacon unit
- Supplied with built-in isolator
- Three selectable tones which comply with EN 54-3:2001
- Suitable for use as a fire alarm system indicator
- Wall mounted
- Weatherproof (IP65 rated)
- Volume control feature: adjustable sound output from 100dB to 92 dB
- Tone and flash synchronisation
- Designed to work with XFP and Kentec fire alarm panels
- Responds to its own individual address
- Can be group addressed – allows multiple sounders to be controlled simultaneously
- No external power supply needed
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and  to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature  changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power  interruption.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby

Automatic Dry Powder 9KG
Automatic Dry Powder 9KG
Designed for fixed automatic protection. Suitable for Class A, B, C fire risks and electrical fires.
The 6kg automatic extinguisher will protect an area up to 20 cubic metres.
This Automatic Extinguisher can be used for the following applications: trucks, small boats, large boats, motor sports and engine/plant rooms.
Fully refillable stored pressure extinguisher, with 68ºC red bulb automatic sprinkler fitted as standard (other bulb temperatures available on request for bulk orders). Fitted with pressure gauge for routine inspection. Bracketry included with extinguisher.

IFS 0.8 MM Fire Resistance Cable 100M Drum
0.8mm Fire Resistance Cable 100M Drum
We supply a full range of Fire Resistance Cables and fire performance cables, often also referred to as fire survival cables, fireproof cables, or simply fire cables.It is designed to resist the spread of fire into a new area. Fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.

Apollo Manual Addressable Call Point with Isolator – XP95
Apollo Manual Addressable Call Point with Isolator – XP95

Fire Extinguisher Safety Seal
Fire Extinguisher Safety Seal
Yellow Tamper Seals, Zip Ties for Fire Extinguishers and Fire Safety

Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon
Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311Â is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00- Certified to EN54 Part 11 & 17.
- Resettable operating element.
- Easy access front reset mechanism.
- Ergonomic reset key (supplied).
- 170° viewable LED.
- Continuity link for cable insulation testing.
- Suitable for semi flush or surface mounting.
- Combined sounder and beacon unit
- Supplied with built-in isolator
- Three selectable tones which comply with EN 54-3:2001
- Suitable for use as a fire alarm system indicator
- Wall mounted
- Weatherproof (IP65 rated)
- Volume control feature: adjustable sound output from 100dB to 92 dB
- Tone and flash synchronisation
- Designed to work with XFP and Kentec fire alarm panels
- Responds to its own individual address
- Can be group addressed – allows multiple sounders to be controlled simultaneously
- No external power supply needed
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and  to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature  changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power  interruption.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby

Automatic Dry Powder 9KG
Automatic Dry Powder 9KG
Designed for fixed automatic protection. Suitable for Class A, B, C fire risks and electrical fires.
The 6kg automatic extinguisher will protect an area up to 20 cubic metres.
This Automatic Extinguisher can be used for the following applications: trucks, small boats, large boats, motor sports and engine/plant rooms.
Fully refillable stored pressure extinguisher, with 68ºC red bulb automatic sprinkler fitted as standard (other bulb temperatures available on request for bulk orders). Fitted with pressure gauge for routine inspection. Bracketry included with extinguisher.

IFS 0.8 MM Fire Resistance Cable 100M Drum
0.8mm Fire Resistance Cable 100M Drum
We supply a full range of Fire Resistance Cables and fire performance cables, often also referred to as fire survival cables, fireproof cables, or simply fire cables.It is designed to resist the spread of fire into a new area. Fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.

Apollo Manual Addressable Call Point with Isolator – XP95
Apollo Manual Addressable Call Point with Isolator – XP95

Fire Extinguisher Safety Seal
Fire Extinguisher Safety Seal
Yellow Tamper Seals, Zip Ties for Fire Extinguishers and Fire Safety

Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon
Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311Â is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Please Call/SMS +254 793 000 111 to confirm product availability.
KSh240,000.00- Certified to EN54 Part 11 & 17.
- Resettable operating element.
- Easy access front reset mechanism.
- Ergonomic reset key (supplied).
- 170° viewable LED.
- Continuity link for cable insulation testing.
- Suitable for semi flush or surface mounting.
- Combined sounder and beacon unit
- Supplied with built-in isolator
- Three selectable tones which comply with EN 54-3:2001
- Suitable for use as a fire alarm system indicator
- Wall mounted
- Weatherproof (IP65 rated)
- Volume control feature: adjustable sound output from 100dB to 92 dB
- Tone and flash synchronisation
- Designed to work with XFP and Kentec fire alarm panels
- Responds to its own individual address
- Can be group addressed – allows multiple sounders to be controlled simultaneously
- No external power supply needed
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- Asenware Convectional heat detector AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
- This detector is designed to provide open area protection and  to be used with most conventional fire alarm panel.
- The conventional rate of rise heat detector uses thermal component to detect the temperature  changing in the environment.
- It has a stable and reliable working performance.
- Two LEDs on each detector provide local 360° visible alarm indication.
- The alarm can be reset only by a momentary power  interruption.
- Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
- Functions as a standard 3Â zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
- 128 x 64 pixel display.
- Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
- Manual release button and two keyswitches.
- 3Â conventional sounder circuits (two x 1st stage, one x 2nd stage).
- Powerful 3A EN54-4 switch mode PSU.
- Wide range of monitored inputs and auxiliary outputs.
- Abort and hold inputs.
- Time-stamped event log.
- RS485 connections for up to 8Â flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
- Wide range of engineering functions.
- Optional relay expansion boards and single gang abort &Â hold buttons
- Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
- System line terminator included.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with color-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Eight detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s active range of conventional fire detectors.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Four detector zone circuits.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Newly designed optical chamber with sealed upper-part and 500 μm holes diameter mesh insect screen
- Bicolour LED: Red for alarm; Green slow flash for standby (optional) and fast flash for trouble (fault or high level of contamination in the optical smoke chamber)
- Drift compensation for sensor drift caused by dust in the chamber
- Sensitivity selection for smoke and heat (by means of EDRV1000 driver)
- Operating mode selection (by means of EDRV1000 driver for ID300 version): Only smoke; Only Heat; AND mode; OR mode; Plus mode
- Complete Diagnostics: view the contamination level in the optical chamber and verify real-time values (by means of EDRV1000)
- Memory of the smoke and temperature levels measured in the five-minute period prior to the last alarm detected
- Vast range of options (selected by means of EDRV1000 driver)
- Bypass plate on base guarantees continuity in the event of removal of the detector from the line
- Four Loop Control Panel, 230Vac, 2 sounder circuits.
- Supports the Morley-IAS protocol
- Dims 391.5 x 390 x 147 (H x W x D)
- Network up to 16 loops (16×1 loop panels, 8×2 loop panels, 4×4 loop panels, or any mix up to max 16 loops)
- True peer-to-peer and fault-tolerant network for high system reliability
- BS5839 part 1 compliant network
- Disable all relays
- Easy 5 key-press set-ups
- Large blue LCD display
- Supports USB upload/download
- Alpha-numeric style keypad and navigation keys
- Option to upload a company logo
- 160 zone compact mimic support
- Panel buzzer ‘mute’ in engineering mode
- Up to 72-hour standby

Automatic Dry Powder 9KG
Automatic Dry Powder 9KG
Designed for fixed automatic protection. Suitable for Class A, B, C fire risks and electrical fires.
The 6kg automatic extinguisher will protect an area up to 20 cubic metres.
This Automatic Extinguisher can be used for the following applications: trucks, small boats, large boats, motor sports and engine/plant rooms.
Fully refillable stored pressure extinguisher, with 68ºC red bulb automatic sprinkler fitted as standard (other bulb temperatures available on request for bulk orders). Fitted with pressure gauge for routine inspection. Bracketry included with extinguisher.

IFS 0.8 MM Fire Resistance Cable 100M Drum
0.8mm Fire Resistance Cable 100M Drum
We supply a full range of Fire Resistance Cables and fire performance cables, often also referred to as fire survival cables, fireproof cables, or simply fire cables.It is designed to resist the spread of fire into a new area. Fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.

Apollo Manual Addressable Call Point with Isolator – XP95
Apollo Manual Addressable Call Point with Isolator – XP95

Fire Extinguisher Safety Seal
Fire Extinguisher Safety Seal
Yellow Tamper Seals, Zip Ties for Fire Extinguishers and Fire Safety

Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon
Apollo XP95 Open Area Weatherproof Addressable Sounder Beacon

Ctec Fire Alarm Control Panel 2 loop Addressable Panel
Ctec Fire Alarm Control Panel 2 loop Addressable Panel

Ctec 1 Loop Addressable Fire Panel
Ctec 1 Loop Addressable Fire Panel

Asenware sounder and flasher
Asenware sounder and flasher
Asenware AW-CSS2166-5 Conventional Fire Strobe Sounder is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
Buy at the Best and Discounted prices in Nairobi kenya

Asenware Convectional heat detector AW-CTD382

Ctec EP203 Automatic Extinguisher Panel
Ctec EP203 Automatic Extinguisher Panel

INIM Conventional control panel with 4 zones expandable to 20
INIM Conventional control panel with 4 zones expandable to 20
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036-4).

C-TEC Standard 8 Zone Conventional Fire Alarm Panel
C-TEC Standard 8 Zone Conventional Fire Alarm Panel

C-TEC Standard 4 Zone Conventional Fire Alarm Panel
C-TEC Standard 4 Zone Conventional Fire Alarm Panel

Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
The AW-CFP2166 series 8 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detectors, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Asenware 4 Zone Fire Alarm Control Panel
Asenware 4 Zone Fire Alarm Control Panel

AW-CTD321 Conventional Fix Temperature Heat Detector
Conventional Fix Temperature Heat Detector AW-CTD321 is a photo-electronic detector using a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panels.
1.Strong Adaptability For Circumstance
2.SMT Design, High Stability
3.40-60vdc Wide Voltage Operating Range
4.Low Standby Current
5.Power Supply Non-Polarized input
6.Twin Led For 360 Visual
7.Flashing Led Power Indicator
8.Remote Led Indicator Output(2-Wire)
9.Metal Shield. Anti-Electromagnetic Interference

Asenware Smoke Detector AW-CSD311
Asenware Smoke Detector AW-CSD311
AW-CSD311Â is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Inim Conventional Heat Detector ID200
Inim Conventional Heat Detector ID200

Conventional Optical smoke detector
Conventional Optical smoke detector

Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
Morley Honeywell Grey DXc4 4 Loop Fire Alarm Panel
